AFX V3.07.03

New features

Improvements

AFX V3.06.05

New features

  • There is now support for the new DOL 119 CO2 sensor. Both the 10000 ppm and 5000 ppm inputs may be used.

Improvements

  • Actuators connected to an ACT-1T Timed Actuator Module now use an automatic reset instead of automatic calibration. An automatic reset periodically fully opens or fully closes the actuator to reset its position to 0% or 100%. It can also be run manually.
  • The update process has been improved to prevent a rare issue where specific module arrangements and configurations caused the update to stall.
  • The automatic reset can now run when the outdoor temperature is less than the set point instead of above it.
  • The influence modifier will now update its effect consistently when the group reading of the modified output changes.
  • The calibrate actuator option can now be accessed correctly in the Actuator Settings screen.

AFX V3.06.04

New features

  • The Auger Manager is now available. The Auger Manager can control feed delivery systems that use one main auger relay to distribute to several line relays.
  • RM-4 relays can now be linked to a Current Sense connected to an IN-4. This allows a relay to work with the Auger Manager and also adds high current alarm shutoff.

Improvements

  • Alarms and reports can now be generated when there are no regular equipment groups. This allows controls with only feed loops and/or the Auger Manager to use the alarms and reports.
  • The Max Runtime for feed loops that are in schedule mode is now editable. This allows you to set a limit on test cycles. The Max Runtime can be edited in the test menu.
  • Output alarms in the Alarm Message Log now show the group of the output that is alarming.
  • Reports now correctly display items with certain special characters.
  • Dropdown menus in the Maintenance Schedule and the Alert Schedule have been improved.

AFX V3.06.01

Improvements

  • The calibrated ranges of actuators with potentiometer, voltage, or timed feedback are now visible in their calibration screen.
  • Improvements have been made to VAC-1 outputs to prevent abnormal motor behaviour.
  • VCM-DC Feedback Sensor alarms will no longer trigger when in Gusty Mode.
  • There have been several improvements to reports.

AFX V3.06.00

New features

The new ACT-1T Actuator Module with timed feedback is now available. It includes the following features:

  • Current monitoring on the open and close relays
  • Timed feedback for position determination
  • Automatic reset — you can configure it to calibrate after a specific number of movements during your selected times of the day. There is an option to disable automatic calibration during cold weather.

Improvements

  • In the Room Management screen, the curve name now displays below 'Assign Curve' if a curve is currently assigned.
  • Input charts and reports now display correct volume totals for water meters.
  • The Water Consumption Report now displays the correct selectable inputs.
  • There have been many additional improvements and fixes for charts and reports.
  • In feed loops, the maximum value for the input alarm delay has been increased to 7200 seconds (2 hours).

AFX V3.05.06

Improvements

  • There is a new Setup Wizard available to guide you through the initial setup of new installations.
  • When you are using an AutoFlex with a Protect Connect, you can now acknowledge alarms generated by the AutoFlex Connect on the control itself or on the Protect Connect.
  • Air Curtain overrides now happen immediately on individual blowers instead of waiting for blower 1 or the Blower Delay. When the last remaining blower has been set to Auto, all blowers will shut off briefly before restarting the inflation sequence from the beginning.
  • When viewed in a web browser, AutoFlex Connect now resizes to fit the browser window.

AFX V3.05.05

Improvements

  • An evaporative cooling modifier has been added to VentGrid. The modifier allows you to reduce the ventilation rate when a cooling duty cycle or evaporative cooling cycle is active.
  • You can now configure feed loop tests to ignore the actuator drop.
  • You can now use timed overrides with VAC-1 and VDC-4 modules.
  • Configurable fallbacks have been added for VentGrid and for each output in traditional staged mode. AutoFlex Connect will use the fallback configuration if there is no valid group reading or there are communication issues.
  • The maximum duration for feed loop duty cycles been increased from 240 to 600 seconds.
  • The default for VentGrid bandwidth has decreased from 10 to 4°C.
  • Static pressure for VentGrids now shows min/max instead of start/stop.
  • If a VCM-DC module fails feedback calibration, it will use the default of 100 pulses as the feedback value.
  • If a VCM-DC module is in feedback mode, the minimum state of the VCM-DC will no longer show the fan going below idle speed while the damper is closed unless the target output is 0. The fan will remain at idle speed in this state.
  • Manager-level users can now access the Room Management screen to change set points and curve days.
  • Air Curtain widgets now flash purple when their modifiers are active.
  • The adjustment spinner for 'Chambers to close' has been removed from the Secondary Modifiers screen for modifiers where it is not required.
  • Modifiers with a comparison set to 'more than' now save properly.
  • Secondary modifiers with inputs on multiple IN-4 modules now activate and deactivate properly.

AFX V3.05.02

New features

  • You can now configure relays to be trigger relays.

Changes

  • The status update frequency has been increased. Manual overrides, alarm triggers, and temperature changes will display more quickly and more reliably.
  • The RM-2 high current shutoff is now forced to be disabled when the high alarm is disabled. The shutoff is automatically enabled when the high alarm is enabled but you can change it to disabled.
  • The following input types and sensors now show their maximum or minimum value more consistently before showing “--” when the reading is too high or too low:
    • 4-20 mA inputs too high or too low:
      DOL-19 CO2
      DOL-114 Temperature and Humidity
    • 0-10 V inputs too high:
      DOL-15 Temperature
      DOL-16 Light
      DOL-53 Ammonia
      DOL-58 Wind Speed, Wind Direction, and Barometric Pressure

Fixes

  • Wind chill group alarm values are now converted correctly when in degrees Fahrenheit.
  • Air curtains with long names are now saved correctly.
  • Cancelling VCM-DC calibration in non-feedback mode no longer prevents the module from returning to normal operation.
  • Reports with RM-2s now correctly show “A” for the Current column header instead of “%”.
  • Wireless VFDs can now be saved in static pressure equipment groups.
  • The screen no longer locks up when scrolling through rooms on the Structure screen.
  • The incorrect text “NaN” no longer displays on screens.
  • Alert log dates are now sorted correctly into days.

AFX V3.04.06

Changes

  • Alert email certificates have been updated in accordance with AWS to enhance security. Previous certificates will become obsolete in the near future.
  • The maximum temperature limit has been increased from 50 to 70°C.
  • The daily refresh now occurs at 8:00 am instead of 10:00 am.
  • The console text will no longer display during a restart.
  • The actuator widget will now display 'actual / expected' instead of 'expected / actual'.
  • An actuator will no longer fully close when the target is close to, but not exactly 0%.

Fixes

  • Network handling has been improved to fix delayed startups caused by poor network quality.
  • RM-2 Relay Modules will no longer display with a red background when the alarm is disabled.
  • The VCM-DC Variable Chimney Module menu now properly displays the overridden status.
  • Protection has been added to prevent an issue where adding static pressure to a ventilation grid would cause a mismatch error between modes.
  • The Feed Consumption Report now shows the correct number of days and proper consumption for the current day.

AFX V3.04

New features

  • Current monitoring
    You can set up an Input Module to monitor the new Current Sense 2 accessory as an input type. The current range can be 0-10, 0-20, or 0-50 amps.
  • A duty cycle output option has been added to fixed stage outputs in the ventilation grid.
  • Herd information
    Herd information can now be entered at an AutoFlex.
    The Herd Report and Audit Report can now be viewed based on population.
  • All output data is now saved to the Phason Cloud.
  • The room setting mode can now be set to change on specific dates and can be overridden for a set duration.

Changes

  • The wind direction secondary modifier is now 180 degrees, rather than the previous 90.